Assessment of Implant Stability: Methods and Recent Advances
Aman Sachdeva, Pankaj Dhawan, Suruch Sindwani
Journal of Advances in Medicine and Medical Research · pp. 1–10 · Published 7 Nov 2015
10.9734/BJMMR/2016/21877Abstract
Achieving primary stability is of greatest importance, at the time of implant placement. A rigid fixation of implant within the host bone, in absence of micromotion is the most critical factor for successful osseointegration. Over the years, several authors have reported various methods in literature to monitor implant stability, which include, tapping the abutment with a metallic instrument, histomorphometry test, removal torque test, cutting torque test, radiography, periotest, and resonance frequency analysis. Resonance frequency analysis (RFA) offers a clinical, objective way to measure stability and presumed osseointegration of implants. The review focuses on different methods used to assess implant stability and recent advances in this field.
Cited by 17
Eda İZGİ, Mehmet ŞİMŞEK · Turkish Journal of Clinics and Laboratory · 2020
Ali Tareef Noaman, Salwan Y. Bede · Journal of Craniofacial Surgery · 2021
Carles Subirà-Pifarré, Cristina Masuet-Aumatell, Carlos Rodado Alonso · Journal of Functional Biomaterials · 2019
Nawfal Hasan Tofan, Ali H Abbas Hussaini · Dental Hypotheses · 2024
Shanthi Vanka, Fatima Abul Kasem, Tasnem Kailani · Evidence-Based Dentistry · 2024
Pankaj Dhawan, Neha Jain, Piyush Tandan · International Journal of Prosthodontics and Restorative Dentistry · 2023
Ali T Noaman, Salwan Y Bede · Journal of Baghdad College of Dentistry · 2022
Related research
- Periodontal Pathogens in Screw and Cement Retained Prosthetic Appliances — shares topic coverage
- Reduction of Bacterial Proliferation by Zirconium Collar in Dental Implants — shares topic coverage
- Use of Prototyping Technology as an Aid for Oral Rehabilitation — shares topic coverage
- Simplified Method of Interimplant Papilla Preservation around Immediate Implant in the Maxillary Aesthetic Zone- A Case Report — shares topic coverage
- A Literature Review on Vertical Adaptation Of Fixed Implant-Supported Prostheses: Conventional System Versus Cad/Cam System — shares topic coverage
Article metrics
Real usage data collected on this platform.
13
Page views
0
PDF downloads
0
Outbound clicks
17
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.