Skip to content
Research Article Open access CC BY 4.0

Assisted Vaginal Delivery - Preference of Vacuum or Forceps among Obstetricians

Vijayalakshmi Gnanasekaran, Shantha Kanamma, Shanthi Dhinakaran, Jikki Kalaiselvi

Journal of Pharmaceutical Research International · pp. 147–155 · Published 25 Nov 2021

10.9734/jpri/2021/v33i51B33524

Abstract

Objective: To determine the instrument preference among obstetricians practicing operative vaginal deliveries and to determine the prevalence and risks of vacuum or forceps Assisted Vaginal Delivery (AVD). Methods: This cross-sectional study was carried out in ACS Medical and Hospital, Chennai. A total of 520 obstetricians were included in the study. An online questionnaire was sent to all obstetricians in Chennai. The choice of procedure for specific circumstances, instrument preference [use of vacuum or forceps] and views on the complications encountered in both vacuum and forceps use at vaginal delivery were explored. For the replies, we computed means and percentages for the entire group and distinct subgroups. Risk assessment of outcome with exposure as suitable p-value was included in the statistical analysis. Results: Response rate for the questionnaire was 97% (504/520). The findings suggest that obstetricians preference was more towards vacuum due to their ease of usage.   Baseline characteristics were similar between the two groups. Failed vacuum due to slipping of the cup was the most common complication faced - 62%, followed by caput succedaneum 25%, both were statistically significant. The most significant finding was that maternal injuries in the vacuum group were only 2% which was way less than those who had forceps delivery (68%) with a p-value of < 0.001. Conclusion: In this research, physician instrument choice is a significant predictor of results that should be taken into account. Use of vacuum for delivery seemed to be the choice of majority of obstetricians [334 (66%)]. Vacuum extractor rather than forceps for assisted delivery appears to reduce maternal morbidity, whereas neonatal injuries were more common in newborns delivered by vacuum. The choice of instrument should be personalized based on the patient's condition and the obstetrician's experience and expertise.

Assisted vaginal delivery vacuum forceps instrumental deliveries and obstericians

Cited by 2

Obstetric factors and neonatal outcomes of depressed skull fractures in newborns

Jihyun Choi, Iseop Cho, Tae Eun Kim · Archives of Gynecology and Obstetrics · 2024

Join point trends of instrumental vaginal deliveries and cesarean sections at the Lagos University Teaching Hospital, Lagos, Nigeria (2002–2017)

Joseph Ayodeji Olamijulo, Zubaida Aliyu, Gbenga Olorunfemi · International Journal of Gynecology & Obstetrics · 2024

Article metrics

Real usage data collected on this platform.

11

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.