Clinical Tests to Determine the Correct Position of Central Venous Catheter in Overweight Patients in Critically Ill Condition

Álvaro José Montiel-Jarquín, Rodolfo Gregorio Barragán-Hervella, Jorge Loría-Castellanos, Eugenio García-Cano, Hugo Alejandro Solis-Mendoza, María del Socorro Romero-Figueroa, Ivet Etchegaray-Morales, Mario Gerardo Herrera-Velasco, Carlos Sánchez-Gazca, Miguel Cruz-Vázquez

Journal of Advances in Medicine and Medical Research · pp. 1–7 · Published 28 Jun 2017

10.9734/JAMMR/2017/34358

Abstract

Objective:  To demonstrate the utility of clinical test to determine the correct placement of the CVC in overweight patients in critical condition. Methods: Cross-sectional Study carried out in the Intensive Care Unit of the High Speciality Medical Unit of Traumatology and Orthopedics from Mexican Social Security Institute during 2014. The variables were age, sex, Body Mass Index and clinical diagnostic test. The placement of the catheter was done percutaneously, once the catheter was placed, clinical tests for determining the correct placement were done, verifying cardiac arrhythmias, test of venous return, measurement of Central Venous Catheter pressure and external length of the catheter. The statistics used was descriptive. Results: Thirty-one patients were included. To all the patients clinical diagnosis tests were performed to verify the correct placement of the Central Venous Catheter (58%). The average Body Mass Index was 26. Of the catheters placed, 29.03% were central and 70.96% were misplaced, according to the chest x-ray. The arrhythmias were presented in 9.67%, with a specificity of 90%, and negative predictive value of 90%. The variations in central venous pressure were presented in 32.25% patients; the sensitivity was 20%, the specificity and negative predictive value were 60% respectively. Conclusion: We found low sensitivity and good specificity for these clinical tests.

Clinical tests critical care Central Venous Catheter.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

14

Page views

0

PDF downloads

1

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.