Development and Validation of the RP-HPLC Method for the Estimation of Chlorocresol and Betamethasone Dipropionate in Semisolid Dosage Formulation
Ashok Khatawakar, Sachin Sakat, Poonam Inamdar, Om Bagade
Journal of Pharmaceutical Research International · pp. 12–22 · Published 14 May 2022
10.9734/jpri/2022/v34i38A36212Abstract
A simple, accurate, reproducible and cost-effective reverse phase HPLC technique for chlorocresol (CRC) as a preservative as well as betamethasone dipropionate (BTD) in bulk drug as well as semi-dose formulations. Snakes were developed during this research. In this method, Discovery HS (150x4.6 mm),was used as the stationary phase and an 80:20 mixture of water and isopropyl alcohol was used as the mobile phase A, and a mixture of acetonitrile plus tetrahydrofuran in the ratio. 70:30 ratio was used as mobile phase B in gradient mode to produce the final product. Approximately 1.00 ml/min of the solution is passed through the chromatograph by pumping it through. The UV detector operates at a wavelength of 240 nm. A validation study in accordance with the ICH Q2 (R1) guidelines is required to demonstrate that the new analytical method meets the reliability characteristics and these characteristics demonstrate the ability of a new analytical method. analysis in maintaining, over time, the basic validation criteria: selectivity, linearity, precision, precision, and specificity. When this method is used for quality control of commercial semi-solid dosage forms of betamethasone dipropionate throughout the day, the stability indicator technique can be used to measure the breakdown of the drug and its products it, as well as to evaluate the results of the tube homogeneity test.
Cited by 0
No indexed citations yet.
Related research
- Real Time Polymerase Chain Reaction versus Enzyme Linked Immunosorbent Assay in the Diagnosis of Cytomegalovirus Infection in Pregnant Women — shares topic coverage
- Home Recording And Video Selection: Their use In A Low-Resource Setting For Epilepsy Diagnosis — shares topic coverage
- Laboratory Performance Evaluation of Wantai HIV 1/2 Rapid Test Kit — shares topic coverage
- Performance of WRF’S Microphysics Options to Increase the Medium Range Rainfall Forecast Accuracy in Tamil Nadu Cauvery Delta Zone — shares topic coverage
- Remote Sensing and GIS Based Crop Acreage Estimation of the Rabi Season Growing Crop of the Middle Gujarat (India) — shares topic coverage
Article metrics
Real usage data collected on this platform.
12
Page views
0
PDF downloads
7
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.