Evaluation of the Intraocular Pressure Measurement in Patients with Primary Open Angle Glaucoma Using Corvis-ST
Maha El Sayed Mabrouk, Mohammed Hosny Nasef, Waleed Abd Elhady Allam, Ahmed Mohamed Ghoneim
Journal of Advances in Medicine and Medical Research · pp. 78–85 · Published 4 Jul 2022
10.9734/jammr/2022/v34i2031471Abstract
Background: The Corneal Visualization Scheimpflug Technology device (Corvis ST tonometry: CST) is a novel noncontact tonometer developed to assess intraocular pressure (IOP) while accounting for the cornea's biomechanical qualities. The aim of this work was to assess reliability and accuracy of corvis-ST tonometer in measurement of IOP in cases of primary open angle glaucoma (POAG). Methods: This prospective comparative non-interventional study included 70 eyes of patients suffering from bilateral POAG and with clear and virgin corneas. Eyes were divided into two groups: group A (40 eyes of POAG) and group B (30 normal eyes). All patients were subjected to: history taking, examination [visual acuity (VA), slit lamp examination, gonioscopy for angle, posterior segment, optic disc evaluation and IOP measurements] and investigations (Pachymetry and Corvis ST). Results: There was a significant negative correlation between non-corrected IOP measured by Corvis and corneal biomechanical index in studied glaucoma patients. There is a positive significant correlation between first and second IOP readings by Corvis. This means that the first and second readings of IOP by corvis with interval 30 minutes between the two readings increased together and decreased together (positive relationship). Conclusions: The IOP measurement in patients with POAG using Corvis-ST has a good reliability.
Cited by 0
No indexed citations yet.
Related research
- Diagnostic Mydriasis: Any Effects on Systolic Blood Pressure? — shares topic coverage
- Is There a Causal Relationship between Myopia and Intraocular Pressure — shares topic coverage
- A Prospective Pilot Study Comparing the Retinal Layer Effects of Two Techniques for Nd: Yag Laser Posterior Capsulotomy — shares topic coverage
- The Effect of Cataract Surgery on the Intraocular Pressure in Eyes with and without Pseudoexfoliation Syndrome — shares topic coverage
- A Study of Selective Laser Trabeculoplasty as Adjunctive Treatment in Patients Affected by Open Angle Glaucoma for Control of Intraocular Pressure in Indian Eyes — shares topic coverage
Article metrics
Real usage data collected on this platform.
4
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.