Skip to content
Research Article Open access CC BY 4.0

Organ Dose Distribution and Estimated Cancer Risk to Paediatric Patients Undergoing Computed Tomography in a Nigerian Tertiary Hospital

C. A. Aborisade, O. C. Famurewa, F. I. Ibitoye, F. A. Balogun

Journal of Advances in Medicine and Medical Research · pp. 1–9 · Published 24 Apr 2019

10.9734/jammr/2019/v29i730105

Abstract

Aims: The aim of this research work is to estimate the organ dose distribution and the associated radiation induced cancer risk for some commonly performed Computerized Tomography (CT) examinations in a tertiary medical facility in South Nigeria. Study Design:  The study was designed to estimate the radiological implications of radiation dose that the paediatric patients were exposed to during routine CT examinations. Place and Duration of Study: Department of Radiology, Obafemi Awolowo University Teaching Hospital Complex, (OAUTHC), Ile-Ife, Nigeria, between August 16,  2011 to August 15 2012. Methodology: Well calibrated thermoluminescent dosimeters (LiF-100) were attached to the skin of paediatric patients such as skull, chest, abdomen, and pelvic in the path of the primary X-ray beam to determine radiation exposure during CT examination. The effective dose was calculated from the equivalent dose obtained from OAUTHC, and the cancer risk associated was estimated by multiply age-dependent lifetime cancer mortality risk (per unit dose) with estimated age-dependent doses produced by various CT examinations. Results: Out of 258 paediatric patients scanned the equivalent dose measured for abdominal CT scan ranged from 23.49 - 55. 26 mSv; skull CT scan ranged from 10.07 – 69.94 mSv and chest CT scan ranged from 8.60 – 31.94 mSv. The peak tube voltage (kVp) used range from 80 – 140 while the exposure current-time product (mA) range from 30 – 300.  The abdominal CT scan had the highest cancer risk ranging from digestive 37.5% to lung cancer risk of 0.4%. The risks estimated in this work were higher than the ICRP recommended value. Reducing the millampere-second setting of the equipment for paediatric without significant loss of radiological information will reduce this risk. Conclusion: In this study the estimated cancer risk to paediatric patients undergoing CT is high.  This is in keeping with findings in a previous study thus emphasizing the need to standardize and optimize radiation dose in paediatric patients undergoing CT in Nigeria so as to keep cancer risk at the minimum.

Paediatric radiology cancer risk CT and dose

Cited by 5

Estudo da Viabilidade de Otimização dos Protocolos Pediátricos em Exames de Tomografia Computadorizada de Crânio

Débora Regina Bonfleur, Jéssica Villa Real, Danielle Filipov · Revista Brasileira de Física Médica · 2021

Diagnostic Reference Level of Radiation Dose and Image Quality among Paediatric CT Examinations in A Tertiary Hospital in Malaysia

Nor Azura Muhammad, Muhammad Khalis Abdul Karim, Hasyma Abu Hassan · Diagnostics · 2020

Hematological and Cytogenetic Effects of X-rays in Cardiac Unit Workers and Catheterization Patients

Haliz Hussein, Asaad Alasady, Khairi MS. Abdullah · Cureus · 2024

Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination

M.K.A. Karim, H.H. Harun, Z. Kayun · Radiation Physics and Chemistry · 2021

Optimization of pediatric brain CT protocols

Débora Regina Bonfleur, Danielle Filipov, Anna Luiza Metidieri Cruz Malthez · Radiation Physics and Chemistry · 2023

Article metrics

Real usage data collected on this platform.

5

Page views

0

PDF downloads

0

Outbound clicks

5

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.