Introduction: Microorganisms are ubiquitous in nature and transient airborne microorganisms have been shown to constitute major health hazards. Aim: This study was carried out to assess the microbial air quality in ten (10) domestic toilets located in mile-3, Alakahia, Choba, Ada-George and Rumuokwuta, Port Harcourt, Rivers state, Nigeria. Methodology: Microbial air quality was sampled using sedimentation techniques. Freshly prepared Nutrient Agar, MacConkey and Sabouraud Dextrose Agar (SDA) plates were placed one meter above the floor of the toilets for 1 hours at different sections of each toilet exposed to an open air. The agar plates were closed and transported to the Laboratory were incubation took place at 37°C for 24 hours and 25°C for 3-5 days for growth of bacteria and fungi respectively. Isolates were characterized and identified by standard microbiological methods. Results: The bacteria isolated were Staphylococcus species 22(22.45%), Bacillus species 20 (20.41%), Enterococcus species 20(20.41%), Escherichia coli 16(16.32%), Micrococcus species 15 (15.31%), Klebsiella species 3(3.06%), and Proteus species 2(2.04%) while Aspergillus species 14(27.45%), Penicillium species 16(23.53%), Fusarium species 10(19.60%), Mucor species 8(15.69%), and Rhizopus species 7(13.73%) were the fungi identified. The highest bacteria colony count before and after flushing were 52.380×103CFU/m3/hr & 67.261× 103CFU/m3/ hrrespectively while the lowest bacteria counts observed before and after flushing 19.047× 103CFU/m3/hr & 39.286×103CFU/m3/hr while the highest and lowest fungal count before and after flushing were 10.119×103CFU/m3/hr & 13.690×103CFU/m3/hr and 5.952×103CFU/m3/hr & 5.953×103CFU/m3/hr respectively. Conclusion: This study shows that considerable numbers of both pathogenic bacteria and fungi particles were released into the air in higher quantity after flushing domestic toilets when compared to air quality before flushing. These organisms have been implicated in major and minor infectious diseases. Inhalation or contact may easily lead to infection especially in immunocompromised individuals and the older adults. To maintain the health of users, it is necessary to carefully manage the environmental factors that promote the growth and multiplication of microorganisms in domestic toilet environment.

Airborne microorganisms domestic toilet health hazards

References (33)

  1. 1 Environmental science and pollution research [DOI]
  2. 2 Gut microbiota: Role in pathogen colonization, immune responses, and inflammatory disease [DOI]
  3. 3 The index of microbial air contamination [DOI]
  4. 4 Review of bioaerosols in indoor environment with special reference to sampling, analysis and control mechanisms [DOI]
  5. 5 Indoor mould exposure, asthma and rhinitis: findings from systematic reviews and recent longitudinal studies [DOI]
  6. 6 Microbial Exchange via Fomites and Implications for Human Health [DOI]
  7. 7 Microbiological assessment of indoor air quality at different hospital sites [DOI]
  8. 8 Microbiological Quality of Indoor Air in University Libraries [DOI]
  9. 9 Methicillin-resistant Staphylococcus aureus : An update on the epidemiology, treatment options and infection control [DOI]
  10. 10 Bioaerosol concentrations generated from toilet flushing in a hospital-based patient care setting [DOI]
  11. 11 Indicators of airborne fungal concentrations in urban homes: Understanding the conditions that affect indoor fungal exposures [DOI]
  12. 12 Assessment and determinants of airborne bacterial and fungal concentrations in different indoor environments: Homes, child day-care centres, primary schools and elderly care centres [DOI]
  13. 13 Extrarenal manifestations of the hemolytic uremic syndrome associated with Shiga toxin-producing Escherichia coli (STEC HUS) [DOI]
  14. 14 The bioaerosols emitted from toilet and wastewater treatment plant: a literature review [DOI]
  15. 15 Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study [DOI]
  16. 16 Strengths and Limitations of Model Systems for the Study of Urinary Tract Infections and Related Pathologies [DOI]
  17. 17 Airborne microflora in the atmosphere of an hospital environment of University of Benin Teaching Hospital (UBTH), Benin City, Nigeria.
  18. 18 Staphylococcus aureus [DOI]
  19. 19 Microbial Air Quality and Bacterial Surface Contamination in Ambulances During Patient Services [DOI]
  20. 20 Biological Contamination of Air in Indoor Spaces [DOI]
  21. 21 Evaluation of airborne fungi and the effects of a platform screen door and station depth in 25 underground subway stations in Seoul, South Korea [DOI]
  22. 22 Indoor air quality : the latest sampling and analytical methods
  23. 23 The Role of Door Handles in the Spread of Microorganisms of Public Health Consequences in University of Benin Teaching Hospital (UBTH), Benin City, Edo State [DOI]
  24. 24 Emerging mould infections: Get prepared to meet unexpected fungi in your patient [DOI]
  25. 25 Sedimentation with the Omeliansky Formula as an Accepted Technique for Quantifying Airborne Fungi
  26. 26 Microbiological Assessment of Indoor Air in Public Toilets across Selected Motor Parks in Owerri Metropolis, Nigeria [DOI]
  27. 27 FEASIBILITY STUDY ON SOLID WASTE MANAGEMENT IN PORT HARCOURT METROPOLIS: CAUSES, EFFECT AND POSSIBLE SOLUTIONS [DOI]
  28. 28 Determination of bacterial load and antibiotic susceptibility testing of bacteria isolated from students’ toilets at Sokoine University of Agriculture, Morogoro, Tanzania
  29. 29 Septic arthritis due to Micrococcus luteus.
  30. 30 Isolation of Fungi and Gram Negative Bacteria from Toothbrushes and Bathroom Bioaerosols [DOI]
  31. 31 WHO guidelines for indoor air quality: dampness and mould
  32. 32 Pharmaceutical Science and Technology [DOI]
  33. 33 Occupational Microbiological Biohazards – Exposure, Detection, and Disease [DOI]

Cited by 2

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.