Skip to content
Research Article Open access CC BY 3.0

The Effect of Large Capsulorhexis (>7mm) on the Stability of Refraction Post Cataract Surgery

Ming Chen

Journal of Advances in Medicine and Medical Research · pp. 86–93 · Published 9 Jan 2012

10.9734/BJMMR/2012/771

Abstract

Purpose: To investigate if the larger capsulorhexis (7mm) is associated with a stable post-operative refraction with Acrysof IQ one-piece IOL (SN60WF, Alcon USA) implantation from 1month to 2 years after cataract surgery. Method: Retrospective chart review was made on 31 eyes of 20 patients. All eyes had uncomplicated phacoemulsification by the author with 7mm capsulorhexis and Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implantation between 4/2007 and 7/2008. IOL Master was used to select the IOL and target refraction was recorded. Refraction data by manifestation in spherical equivalent (SE) at one month, 3 month and 2 years were recorded and input to SPSS19. Result: The mean refractions in spherical equivalent (SE) were statistically significant and excellent positively correlated among the preoperative target refraction (IOL master), one month post-op, three months post-op and two years post-op. P<0.01, Pearson correlation coefficient: r>+0.9 (95%CI 0.91 to 0.98) Conclusion: The 7mm capsulorhexis with Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implanted eyes demonstrated refractive stability from 1 month up to 2 years post operation.

Cataract surgery phacoemulsification capsulorhexis size stability of refraction pseudoexfoliation

References (6)

  1. 1 Capsular tension ring implantation after capsulorhexis in phacoemulsification of cataracts associated with pseudoexfoliation syndrome [DOI]
  2. 2 Post cataract-intraocular lens (IOL) surgery opacification [DOI]
  3. 3 Cataract surgery in pseudoexfoliation syndrome [DOI]
  4. 4 The Effect of Capsulorhexis Size on Development of Posterior Capsule Opacification: Small (4.5 to 5.0 mm) versus Large (6.0 to 7.0 mm) [DOI]
  5. 5 Performance of the 1CU accommodating intraocular lens in relation to capsulorhexis size [DOI]
  6. 6 Drug-induced intraocular lens movement and near visual acuity after AcrySof intraocular lens implantation [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

17

Page views

0

PDF downloads

17

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.