Tissue Penetration of Bipolar Electrosurgery at Different Power Settings

Rupert Ricks, Suzanne Hopcroft, Manish Powari, Andrew Carswell, Phillip Robinson

Journal of Advances in Medicine and Medical Research · pp. 1–6 · Published 7 Jun 2017

10.9734/BJMMR/2017/33773

Abstract

Introduction: Bipolar electro-surgery is used in all disciplines of surgery to aid in haemostasis. Although common sense dictates tissue penetration will be effected by power settings, no formal evaluation of this effect has been made. We performed an experiment to accurately measure the tissue penetration of bipolar diathermy at different strengths. Materials and Methods: Laboratory study using a porcine liver model. Different wattages (10–40 W) of bipolar electro-surgery were applied to deceased porcine liver, with and without fascial covering for a fixed duration. The tissue penetration was measured with a light microscope in two planes, horizontal and perpendicular. The data was compared with a Spearman Rank correlation coefficient calculation. Results: For both fascia and non fascia covered liver there was a statistically significant correlation between increasing power and superficial spread of tissue penetration (Non fascia rho=0.3604, p =0.05) (Fascia rho=0.893, p =0.0068). No such correlation was noted between burn depth and wattage (Non fascia rho=-0.75, p =0.93) (Fascia rho = 0.714, p = 0.0713). There was a statistically significant correlation between the diameter and depth of tissue penetration for fascia covered tissue (rho 0.893, p = 0.0068) but not for non fascia covered tissue (rho 0.3604, p =0.42). Discussion: There is a clear relationship between the power setting of electro surgery and superficial spread of tissue damage however the effects of power setting and deep tissue penetration are not so clear. Interestingly, maximum tissue effects were not encountered at the higher power settings but between 20 and 30 W.

Electro surgery animal model medical device safety haemostatic techniques

Cited by 5

A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods

Bambang Guruh Irianto, Levana Forra Wakidi, Ade Ryan Endarta · Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics · 2025

Design and Testing of Electrosurgery Unit

Meilia Safitri, Adrian Pranata, Muhammad Irfan · Journal of Fuzzy Systems and Control · 2023

Water-cooled microwave ablation array for bloodless rapid transection of the liver

Qiang Yang, Wei Li, Zubing Chen · International Journal of Hyperthermia · 2021

Comparing postoperative outcomes using electrocautery versus cold-knife de-epithelialization of dermal fat graft in parotidectomy reconstruction

Samantha J. Terhaar, Lea McDaniel, Christopher Badger · American Journal of Otolaryngology · 2022

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

0

Outbound clicks

5

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.