Use of Sensors in Rehabilitation of Patients Undergoing Knee Arthroplasty: A Systematic Review
Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Adryan Tyrone Alves de Morais, Mariana Bessa Marinho, Enzo Boaventura Sandes, Matheus Maciel Machado, Rodolfo Borges Parreira, Verônica Cimolin, Cláudio Santili, Cláudia Santos Oliveira
Journal of Advances in Medicine and Medical Research · pp. 459–475 · Published 26 Dec 2025
10.9734/jammr/2025/v37i126031Abstract
Aims: To characterize the use of inertial sensors for assessing mobility, function, and gait in patients undergoing unilateral knee arthroplasty for advanced osteoarthritis. Study Design: Systematic review. Place and Duration of Study: Searches were performed in PubMed, Embase, Scopus and Web of Science databases with no restrictions on date, language, or disease severity. Study selection was completed in 2025. Searches were last performed in 2025. Methodology: This review was registered with PROSPERO (CRD420251002284) and conducted according to PRISMA guidelines. Two independent reviewers screened titles, abstracts, and full texts using predefined inclusion and exclusion criteria. Risk of bias was assessed using a 10-item adapted Downs & Black scale. Data on study populations, experimental protocols, and gait parameters were extracted and synthesized descriptively. Results: Twenty-one cross-sectional studies were included, comprising 758 patients post-TKA and approximately 210 healthy controls. Inertial sensors ranged from 1 to 15 units, most placed on the lower back or pelvis. Walking protocols spanned 6–40 m courses, treadmill tests, oval circuits, and "free-living" monitoring. The primary parameters collected were spatiotemporal (speed, cadence, step length, phase durations) and kinematic (knee joint angles and pelvis/trunk movements). Studies demonstrated good reliability (ICC > 0.85) and accuracy (< 5° angular error). None explicitly investigated differences by prosthesis type. Findings reveal persistent spatiotemporal deficits and kinematic alterations following TKA. Conclusion: Wearable inertial sensors appear to be valid and feasible tools for capturing mobility, function, and gait outcomes after knee arthroplasty. However, substantial methodological heterogeneity (e.g., sensor placement, sampling rates, assessment protocols, and outcome definitions) limits cross-study comparability and precluded meta-analysis. Standardization of protocols and improved reporting, together with higher-quality comparative studies (including evaluation of implant design effects), are priorities to support clinical implementation.
Cited by 0
No indexed citations yet.
Related research
- The Role of Sensor Based Insole as a Rehabilitation Tool in Improving Walking among the Patients with Lower Limb Arthroplasty: A Protocol for Systematic Review — shares topic coverage
- The Psychological Impact of Sports Injuries among Ghanaian University Athletes — shares topic coverage
- Functional Outcome in Polytrauma Patients Undergoing Orthopedic Surgery Using Lower Extremity Functional Scale in a Tertiary Center in Bangladesh — shares topic coverage
- Effectiveness of Dry Needling, Dynamic Cupping and Instrument-assisted Soft-tissue Mobilisation in Plantar Fasciitis: A Critical Narrative Review of Individual and Combined Use — shares topic coverage
- KinesioTape® Influence on Female Functional Ankle Instability: Preliminary Findings — shares topic coverage
Article metrics
Real usage data collected on this platform.
43
Page views
0
PDF downloads
10
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.