Skip to content
Research Article Open access CC BY 4.0

Development and Validation of Ultra High Performance Liquid Chromatographic (UHPLC) Method for the Determination of Roxithromycin in the Broiler Plasma

R. D. Singh, S. K. Mody, H. B. Patel, V. N. Sarvaiya, B. R. Patel, S. B. Gondaliya

Journal of Pharmaceutical Research International · pp. 1–8 · Published 21 Nov 2019

10.9734/jpri/2019/v31i630318

Abstract

Aims: The present study was designed to develop and validate the UHPLC method for quantitative determination of roxithromycin, a macrolide antimicrobial drug, in broiler plasma for the application of pharmacokinetic studies. Methodology: UHPLC apparatus comprised of ultraviolet (UV) detector was used in the present study. Chromatographic separation was performed by using reverse phase C18 column. Mobile phase was combination of buffer and 55 acetonitrile in the ratio of 55: 45. Buffer part used was 0.1% trifluoroacetic acid (v/v) having pH of 2.1. Erythromycin was used as an internal standard. Isocratic elution mode was employed with flow rate of 1 ml/min and effluents were monitored at wavelength of 220 nm. Liquid-liquid extraction using ice-cold acetonitrile was performed to extract roxithromycin from plasma samples. The data integration was performed using Chromeleon™ version 6.8 software. Results: The linear calibration curve with a mean correlation coefficient (R2) value of 0.9999 was observed for concentrations ranging from 0.20 to 12.80 µg/ml. At any concentration, accuracy was not found to be less than 90%. The mean extraction recovery (n=5) for concentrations of 0.40 µg/ml was 81.36%. The calculated intraday and interday C.V. % was not more than 7.70% and 9.42%, respectively, at any concentration studied. The specificity of the analysis was reflected by the narrow range of retention time ranging between 6.983 to 7.178 minutes. LOD and LOQ of the method under investigation were calculated as 0.131 and 0.398 µg/ml, respectively. Conclusion: A reliable, reproducible, accurate, precise, specific and sensitive method for analysis of roxithromycin in broiler plasma was developed and validated for application in the pharmacokinetic study of the roxithromycin.

UHPLC roxithromycin method validation broiler plasma.

References (14)

  1. 1 Guidelines and recommendations for antimicrobial minimum inhibitory concentration (MIC) testing against veterinary mycoplasma species [DOI]
  2. 2 Macrolide Antibiotics: Binding Site, Mechanism of Action, Resistance [DOI]
  3. 3 The use of antimicrobial agents in broiler chickens [DOI]
  4. 4 Quantitative determination of the macrolide antibiotics erythromycin, roxithromycin, azithromycin and clarithromycin in human serum by high-performance liquid chromatography using pre-column derivatization with 9-fluorenylmethyloxycarbonyl chloride and fluorescence detection [DOI]
  5. 5 Determination of erythromycin, clarithromycin, roxithromycin, and azithromycin in plasma by high-performance liquid chromatography with amperometric detection [DOI]
  6. 6 Roxithromycin [DOI]
  7. 7 High-performance liquid chromatographic assay of erythromycin and its esters using electrochemical detection [DOI]
  8. 8 Determination of roxithromycin in rat lung tissue by liquid chromatography–mass spectrometry [DOI]
  9. 9 Determination of roxithromycin in human plasma by HPLC with fluorescence and UV absorbance detection: Application to a pharmacokinetic study [DOI]
  10. 10 Liquid Chromatographic Determination of Roxithromycin: Application to Stability Studies [DOI]
  11. 11 Determination of roxithromycin in human plasma by high-performance liquid chromatography with spectrophotometric detection [DOI]
  12. 12 Analysis of erythromycin and roxithromycin in plasma or serum by high-performance liquid chromatography using electrochemical detection [DOI]
  13. 13 High-Performance Liquid Chromatographic Determination of Roxithromycin in Tablets [DOI]
  14. 14 Determination of Roxithromycin by Liquid Chromatography/Mass Spectrometry after Multiple-Dose Oral Administration in Broilers [DOI]

Cited by 3

Showing 1 of 3 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

14

Page views

0

PDF downloads

12

Outbound clicks

3

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.