Abstract

This paper discusses the effectiveness of installing two types of FACTS devices, namely STATCOM and DVR to enhance the fault ride through (FRT) capability of a doubly fed induction generator (DFIG) applied in wind energy conversion systems (WECS). The response of the DFIG to a 3-phase ground fault is investigated with each of these devices. Comparing the stator and rotor voltages, stator and rotor currents, active and reactive power, of the two investigated systems is presented. PI controllers are employed to allow the rotor speed to follow the turbine speed and to adjust the applied rotor voltage magnitude and phase angle according to the wind turbine speed for maximum power tracking. This is achieved by controlling the two PWM converters connected between the rotor circuit and the electrical grid. Results showed a better FRT when using the STATCOM device with the DFIG.

Fault ride through DFIG dynamic voltage restorer STATCOM

References (14)

  1. 1 Wind Power in Power Systems [DOI]
  2. 2 Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip [DOI]
  3. 3 Control of a Doubly Fed Induction Generator in a Wind Turbine During Grid Fault Ride-Through [DOI]
  4. 4 Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions [DOI]
  5. 5 Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators [DOI]
  6. 6 Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid Faults [DOI]
  7. 7 Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind Turbine [DOI]
  8. 8 A Series-Dynamic-Resistor-Based Converter Protection Scheme for Doubly-Fed Induction Generator During Various Fault Conditions [DOI]
  9. 9 Impacts of Symmetrical and Asymmetrical Voltage Sags on DFIG-Based Wind Turbines Considering Phase-Angle Jump, Voltage Recovery, and Sag Parameters [DOI]
  10. 10 Enhancing Low-Voltage Ride-Through Capability and Smoothing Output Power of DFIG With a Superconducting Fault-Current Limiter–Magnetic Energy Storage System [DOI]
  11. 11 Unbalanced Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine With Series Grid-Side Converter [DOI]
  12. 12 Reinforced Control and Operation of DFIG-Based Wind-Power-Generation System Under Unbalanced Grid Voltage Conditions [DOI]
  13. 13 Enhanced Control and Operation of DFIG-Based Wind Farms During Network Unbalance [DOI]
  14. 14 Analysis of the by-pass resistance of an active crowbar for doubly-fed induction generator based wind turbines under grid faults

Cited by 5

LVRT capability enhancement in the grid-connected DFIG-driven WECS using adaptive hysteresis current controller

P. Jayanthi, D. Devaraj · Environment, Development and Sustainability · 2021

Mitigation of faults in grid-connected wind-driven single machine brushless double-fed induction generator

M. Nashed, M. Eskander, M. A. Saleh · Indonesian Journal of Electrical Engineering and Computer Science · 2019

Showing 4 of 5 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

17

Page views

0

PDF downloads

0

Outbound clicks

5

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.