Flexural Behavior of Lapped Connections in Multi-span Cold-formed Z-purlins

K. M. El-Sayed, N. N. Khalil, A. A. Zaky

Advances in Research · pp. 1–16 · Published 15 Jul 2015

10.9734/AIR/2015/18797

Abstract

Aims: Study the flexural behavior of the lapped connections in multi span cold-formed steel Z sections systems. Study Design: The effect of overlap length of the lapped connections was investigated in order to achieve the optimum overlap length/depth ratio. Different bolts arrangements were studied to connect lap splice. Also, a new method using epoxy was supposed and studied to connect lap splice. The effect of web stiffening and flange stiffening of the lapped connection were also investigated in this study. Place and Duration of Study: The R.C. and Materials laboratory, Benha Faculty of Engineering, Benha University, Egypt, between February 2013 and May 2015. Methodology: Seventeen full scale specimens with lapped connections were prepared and experimentally tested taking into account the variables of this study. Results: The experimental results included ultimate load, vertical deflection at mid-span and mode of failure. Conclusion: As expected, the length of lapped connection clearly improved the flexural behavior of the tested specimens. The bolts arrangement at lap splice was very important in increasing the strength and stiffness of lapped connection. The experimental results showed that using epoxy was a practical and good method to connect lap splice. Both web stiffening and flange stiffening delayed the local buckling of lapped connection. However, the flange stiffening produced a more improvement of local buckling resistance.  

Purlins overlaps cold-formed connection

References (6)

  1. 1 Journal of constructional steel research [DOI]
  2. 2 Analysis and design of lapped connections between cold-formed steel Z sections [DOI]
  3. 3 Moment resistance and flexural rigidity of lapped connections in multi-span cold-formed Z purlin systems [DOI]
  4. 4 Analytical prediction on deformation characteristics of lapped connections between cold-formed steel Z sections [DOI]
  5. 5 Structural behavior of lapped cold-formed steel Z sections with generic bolted configurations [DOI]
  6. 6 Structural performance of modern roofs with thick over-purlin insulation—Experimental investigation [DOI]

Cited by 2

Flexural behavior of cold-formed steel Z-purlin overlapped connections

A. E. Khalil, Sherif A. Mourad, M. Hanna · Structures · 2025

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

41

Page views

0

PDF downloads

1

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.