Investigation of Hall Effect on Hydromagnetic Blood Flow in an Inclined Stretching Permeable Vessel of Patients
AKANBI Olumuyiwa Olawale, JESUSINA Babatunde Mofolusho
Journal of Engineering Research and Reports · pp. 485–509 · Published 26 Dec 2025
10.9734/jerr/2025/v27i121754Abstract
The present work provides a computational analysis with applications to magnetohydrodynamic (MHD) blood flow that goes beyond standard models by incorporating Hall currents, ion-slip phenomena, and various other fundamental factors that are deeply interrelated within the context of blood flow in a permeable and extending blood vessel. At the heart of this research is its novel fundamental mathematical model that combines within one overarching theoretical construction of the fundamentals of porous medium flow resistance, buoyancy forces caused by purely thermal as well as solutal processes, and viscous dissipation. Notably, such an integrated research model fills an absolutely fundamental gap in current research findings that have treated these phenomena one by one. The partial differential equations that are dominant are made nondimensional and transformed into a set of nonlinear ordinary differential equations that are solved to a high degree of accuracy by the bvp4c solver function in MATLAB. Validation results indicate that the present numerical solution compares perfectly with existing benchmark solutions with no error (maximum relative error ¡ 0.02%). What is perhaps most enlightening is the sensitivity analysis indicating complex, even counterintuitive, dependencies with key parameters in electromagnetic phenomena. For example, the Hartmann number (Ha) has a DOUBLE role; that is, with increasing values of (Ha) from 0.1 to 1.0, there is a 42% reduction in the main flow but, due to the coupling with Hall currents, there is an impressive 300% enhancement in secondary flow. A more dramatic effect is found with the Hall parameter (m), wherein an increase from 0.5 to 5.0 leads to an impressive 400% increase in secondary flow speeds with 35% less electromagnetic braking. These findings not only deepen our fundamental understanding of MHD biofluid dynamics but also highlight practical pathways for controlling blood flow in applications such as magnetic drug delivery, targeting and lab-on-a-chip diagnostics where fine tuned electromagnetic tuning could replace invasive mechanical interventions.
Cited by 0
No indexed citations yet.
Related research
- Exposure to Mild Hyperbaric Oxygen Increases Blood Flow and Resting Energy Expenditure but not Oxidative Stress — shares topic coverage
- MHD Natural Convective Oscillatory Flow in Bifurcating Blood Capillaries — shares topic coverage
- Impact of Thermal Radiation and Heat Source on MHD Blood Flow with an Inclined Magnetic Field in Treating Tumor and Low Blood Pressure — shares topic coverage
- On Thermal Factor and MHD Mixed Convective Oscillatory Blood Flow in a Bifurcating Artery — shares topic coverage
- A Blood Flow Model of a Bifurcating Artery — shares topic coverage
Article metrics
Real usage data collected on this platform.
11
Page views
0
PDF downloads
7
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.