Measurement of Patient Radiation Doses during Certain Diagnostic Radiography Procedures
Journal of Advances in Medicine and Medical Research · pp. 1–8 · Published 9 Nov 2015
10.9734/BJMMR/2016/22386Abstract
Aims: The aims of this study were to measure the radiation dose to patients in certain routine x-ray examinations and to estimate organs equivalent and effective doses. Study Design: This prospective study included 220 adult patients who underwent 9 radiographic X ray imaging procedures. Place and Duration of Study: This study was conducted Sharg Elneel Model Hospital (A), Fidail Hospital (B), Al-Amal Hospital (C) and Medical Corps Hospital (D), Khartoum state, Sudan, between June, 2013-August, 2015. Methodology: The entrance surface air kerma (ESAK) was measured for four radiographic examinations using thermo luminescence dosimeters (TLD-GR200A). A total of 220 patients were examined in four hospitals. Results: The mean ESAK (mGy) for the chest, hand, knee joint, leg, shoulder, foot, arm, ankle and lumbar spine were 0.40±0.04, 0.36±0.03, 0.64±0.07, 0.39±0.04, 0.35±0.02, 0.54±0.02, 0.26±0.02, 0.46±0.03 and 1.98±1.1, respectively. The overall effective dose was 0.16±0.05 mSv. Conclusions: The results of ESAK were comparable with previous studies. Patient’s doses showed wide variations in the same types of x-ray examination due to the choice of exposure factors, technique, focus-to-film distance, filter, film-screen speed and the output of the x-ray units and processor quality were used.
Cited by 3
N.A.Baharul Amin, Nadin Jamal Abualroos, R. Zainon · Radiation Physics and Chemistry · 2020
Showing 1 of 3 known citations — external sources report more than can currently be individually listed.
Related research
- Radiographic Anatomy of the Canine Appendicular Skeleton — shares topic coverage
- Radiographic Anatomy of the Abdomen of Local Breed Dogs — shares topic coverage
- Cardiotoxic Assessment of Radiographic Developer Effluent in Wistar Rats — shares topic coverage
- Comparison of the Radiopacity of Zinc Oxide-eugenol Cements using Different Radiographic Methods — shares topic coverage
- Clinical Evaluation, Diagnosis and Surgical Management of Traumatic Pharyngitis in a Non-descript Cattle — shares topic coverage
Article metrics
Real usage data collected on this platform.
10
Page views
0
PDF downloads
1
Outbound clicks
3
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.