Microbiological Assessment of Indoor Air Quality in Selected Patient Wards at a Tertiary Hospital in Nigeria

Sylvanus Akpak Upula, Ibiang Arikpo Oka, Uchenna Eze Ije

Annual Research & Review in Biology · pp. 19–29 · Published 22 Aug 2023

10.9734/arrb/2023/v38i630589

Abstract

Aims: Patients are at higher risk of nosocomial infections from pathogenic microbes contaminating the indoor air of hospitals. This study evaluated selected patient wards at University of Calabar Teaching Hospital (UCTH), for bacterial and fungal contaminants. The study also determined the microbial contamination level when compared to recommended sanitary standards. Methodology: To determine microbial load, petri-plate gravitational settling method was used. The set-ups were exposed for one hour (at morning and noon) for passive sampling onto growth media plates, in accordance with the 1/1/1 scheme as stipulated by the index of microbial air contamination standard. Petri-plates were subsequently covered with lids and placed in a cold box. Samples were then transported to the laboratory for further evaluation. Sampling was performed in duplicates within three months, and further analysis were conducted based on standard protocols. Mean counts of bacteria and fungi was recorded and expressed as colony forming units (CFU/m3). Results: Microbial counts in all wards surveyed ranged from ‘intermediate’ to ‘high’ when compared to the sanitary standards of the European Commission for non-industrial premises. However, the counts were within the WHO acceptable sanitary standard (<1000 CFU/m3). Eleven bacterial genera and seven fungal genera were identified. Isolated bacteria were Staphylococcus aureus (18.3%), CoNS (6.7%), Bacillus sp (13.3%), Streptococcus spp (6.7%), Corynebacterium sp (1.7%), and Micrococcus sp (1.7%), Pseudomonas aeruginosa (15%), Escherichia coli (10%), Klebsiella pneumoniae (10%), Acinetobacter baumannii (8.3%), Salmonella sp (5%) and Enterobacter sp (3.3%). Conversely, isolated fungal contaminants were A. niger (25.9%), A. flavus (20.4%), Penicillium sp (16.7%), Candida sp (9.3%), Rhizopus sp (3.7%), Mucor sp (7.4%), Cladosporium sp (14.8%), and Fusarium sp (1.9%). Conclusion: Regular monitoring of indoor air quality in health-care settings is encouraged to effectively guide infection prevention and control strategies and to limit nosocomial infections occurrence.

Bioaerosols hospital wards indoor air nosocomial infections ventilation

References (7)

  1. 1 Microbiological Indoor and Outdoor Air Quality of Two Major Hospitals in Benin City, Nigeria
  2. 2 Passive air sampling: the use of the index of microbial air contamination. [DOI]
  3. 3 Assessment of Microbiological Quality of Indoor Air at Different Hospital Sites of Dilla University: A Cross-Sectional Study [DOI]
  4. 4 Bacteriological Assessment of the Indoor Air of Different Hospitals of Kathmandu District [DOI]
  5. 5 High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia [DOI]
  6. 6 Assessment of microbiological indoor air quality in a public hospital in the city of Agadir, Morocco [DOI]
  7. 7 International Journal of Microbiology [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

45

Page views

0

PDF downloads

10

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.