Skip to content
Research Article Open access CC BY 4.0

Model Development for Residual Chlorine

M. T. Bello, M. H. Bichi

Journal of Engineering Research and Reports · pp. 40–47 · Published 31 Aug 2023

10.9734/jerr/2023/v25i8956

Abstract

The research is to develop a mathematical model for the decay of residual chlorine at the nodes and compare with results from Epanet 2.0. All the influencing parameters of initial chlorine Ccl(init(o)), bulk decay (Kb), wall decay (KW) and travel time (t), were well represented and the equation is developed applying the differential form of the first order chlorine decay model, describing reactions occurring in the bulk fluid and at the pipe wall, which was transformed in to chlorine concentration-based integral expression Ccl (t) =Ccl (o).e-kt ,  is the free chlorine (HOCL) concentration (mg/l) at time (t), which is also called the residual chlorine. is the chlorine concentration at time zero, which is the initial chlorine concentration in the entire water distribution systems. KW is the pipe wall decay coefficient of the particular water distribution pipe network directly affected by initial concentration. K is expressed in the study as the decay due to the quality of water, known as bulk decay coefficient (kb), per unit hour (t=1) at any particular node per hour. he developed mathematical model was a reflection of the reality in the study area Rcl (n)=Ccl (init). KW. е-Kb . The results of the model at nodes 31, 12, 13, 14, 18, 10, 17, 15, 20 and 21 are 0.18 mg/l, 0.19 mg/l, 0.19 mg/l, 0.19 mg/l, 0.19 mg/l, 0.19 mg/l, 0.20 mg/l, 0.19 mg/l, 0.20 mg/l, 0.19mg/l, respectively. Epanet 2.0 results for the same nodes were determine to be 0.17 mg/l, 0.21 mg/l, 0.22 mg/l, 0.20 mg/l, 0.21 mg/l, 0.21 mg/l, 0.25 mg/l, 0.24 mg/l, 0.20 mg/l, 0.20 mg/l, 0.18 mg/l. The correlation between the developed mathematical model residual chlorine results and Epanet 2.0 results gives moderate correlation of 0.561, signifying 60% pearson correlation and 0.01, 2-tailed significance level at 99%.

Mathematical model residual chlorine epanet 2.0 bulk decay and wall decay coefficients

References (7)

  1. 1 Factors which control bulk chlorine decay rates [DOI]
  2. 2 A reactive species model for chlorine decay and THM formation under rechlorination conditions [DOI]
  3. 3 Modeling Distribution System Water Quality: Regulatory Implications [DOI]
  4. 4 Modelling chlorine residual decay as influenced by temperature [DOI]
  5. 5 Optimal Calibration Method for Water Distribution Water Quality Model [DOI]
  6. 6 An Efficiency Assessment of Lower Usuma Water Treatment Plant in Abuja Metropolis, Nigeria [DOI]
  7. 7 Critical Inquiry and Use as Action. The Expanding Scope of Evaluation Use [DOI]

Cited by 2

Modeling the factors affecting residual chlorine decay in the water distribution network of Abuja, Nigeria

Begmyrat Kulmedov, Emre Eroglu, Nurmurat Kandymov · Water Quality Research Journal · 2025

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

7

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.