Research on Low Voltage Ride through Capability of Offshore Wind Farm Grid Integration Based on Dynamic Reactive Power Compensation
Journal of Engineering Research and Reports · pp. 219–229 · Published 5 May 2026
10.9734/jerr/2026/v28i51893Abstract
The rapid expansion of offshore wind energy and its integration into weak power grids have introduced significant challenges to system stability, particularly under fault conditions that cause voltage sags. Ensuring adequate Low Voltage Ride Through has become essential for maintaining grid reliability and preventing large-scale disconnections of wind farms.To address voltage sags caused by short-circuit faults during the grid integration of large-capacity offshore wind farms via weak networks, this paper establishes a simulation model of a permanent magnet synchronous generator (PMSG)-based offshore wind farm in the PSAT platform. Taking the Critical Clearing Time (CCT) as the core evaluation index, the Low Voltage Ride-Through (LVRT) capability is systematically assessed. By simulating short-circuit disturbances, the transient voltage response at the point of common coupling is analyzed, followed by a comparative evaluation of the voltage support effects of three dynamic reactive power compensation devices: Static Var Compensator (SVC), Static Synchronous Compensator (STATCOM), and Unified Power Flow Controller (UPFC). Results indicate that the rational configuration of dynamic reactive power compensation effectively mitigates voltage drops, significantly extends the CCT, and enhances transient stability margins. The distinct response characteristics and support efficacies of different devices are clarified, providing a theoretical foundation for optimizing LVRT strategies and selecting compensation equipment in offshore wind integration.
Cited by 2
Ling Xu, Le Zhao · 2026 8th International Conference on Energy Systems and Electrical Power (ICESEP) · 2026
Showing 1 of 2 known citations — external sources report more than can currently be individually listed.
Related research
- Applied the Software of MATLAB to Calculate the Critical Clearing Time in Power System — shares topic coverage
- Transient Voltage Stability Analysis of Offshore Wind Power Systems — shares topic coverage
Article metrics
Real usage data collected on this platform.
23
Page views
0
PDF downloads
4
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.