Skip to content
Research Article Open access CC BY 4.0

RP-HPLC Method Development and Validation for the Estimation of Lumefantrine in Bulk Drug

Ashish Sethiya, R. P. S. Rathore

Journal of Pharmaceutical Research International · pp. 226–231 · Published 14 Dec 2021

10.9734/jpri/2021/v33i56B33948

Abstract

Lumefantrine is an antimalarial agent used to treat acute uncomplicated malaria. It is administered in combination with artemether for improved efficacy. This combination therapy exerts its effects against the erythrocytic stages of Plasmodium spp. and may be used to treat infections caused by P. falciparum and unidentified Plasmodium species, including infections acquired in chloroquine-resistant areas. A reversed-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for the estimation of lumefantrine in bulk drug. The separation was achieved on Thermo C18 analytical column (250 mm × 4.6 mm i.d., 5.0 μm) using 10mM KH2PO4: acetonitrile  (pH adjust 3.0 with OPA) in the ratio 20:80 v/v as mobile phase and at a flow rate of 1.0 ml/min. Detection was carried out using a UV detector at 240nm. The total chromatographic analysis time per sample was about 6.0 min with lumefantrine eluting at retention time of about 3.225 ± 0.001min. The method was validated for accuracy, precision, specificity, linearity and sensitivity. Validation studies demonstrated that this HPLC method is simple, specific, rapid, reliable and reproducible. The standard curve was linear over the concentration range of 5-25 μg/ml with r2 close to one (0.999). The limit of detection (LOD) and limit of quantitation (LOQ) obtained for lumefantrine were 0.25 μg/ml and 0.75μg/ml respectively. The high recovery and low relative standard deviation confirm the suitability of the proposed method for the determination of lumefantrine in bulk drugs.

Lumefantrine RP-HPLC ICH guidelines antimalarial agent

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

2

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.