Skip to content
Research Article Open access CC BY 4.0

Validation of Electrical Cardiometry Measurements Compared to Transthoracic Echocardiography in Fluid Responsiveness in Sepsis

Mohammed Said El Sharkawy, Mohammed Shebl Abdelghany, Ahmed Ali El Dabe, Ahmed Ali Abd El Hafez

Journal of Advances in Medicine and Medical Research · pp. 10–20 · Published 26 Apr 2022

10.9734/jammr/2022/v34i1131359

Abstract

Background: Severe sepsis and septic shock patients have a broad range of hemodynamic characteristics. A better understanding of the hemodynamic profile and response to therapy can lead to more effective treatment and consequently a lower mortality and morbidity. The current research work was designed to investigate the non-invasive diagnostic accuracy and agreement of electrical cardiometry (EC) with transthoracic echocardiography (TTE) for fluid responsiveness in sepsis. Methods: This prospective cohort study was assessed on 25 patients showing clinical criteria of sepsis and developed hypotension. All patients were subjected to simultaneous measurement by EC and TTE. Fluid was administered if stroke volume (SV) measured by TTE increased by > 10% after the fluid challenge up to 30 mL/kg else vasopressor infusion was initiated. Results: Electrical cardiometry significantly predicted fluid responsiveness in sepsis compared to TTE with 81.4% sensitivity and 90% specificity. There was an insignificant difference between SV index (SVI), cardiac index (CI), SV, and cardiac output (CO) estimated by TTE and by EC. The mean bias between SV measured by TTE and by EC was 0.25 ± 3.4 ml. The mean bias between TTE and by EC was 0.10 ± 1.78 mL/m2 in SVI, 0.01 ± 0.35 L/min in CO and 0.009 ± 0.18 L/min/m2 in CI. Conclusions: Electrical cardiometry significantly predicted fluid responsiveness in sepsis compared to TTE with good agreement between measurements of EC and TTE.

Sepsis fluid responsiveness electrical cardiometry transthoracic echocardiography

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

1

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.