X-ray Diffraction Analysis to Clarify the Unusual Origin of an Intraocular Foreign Body

Francisco J. Ascaso, Javier Blasco

Journal of Advances in Medicine and Medical Research · pp. 228–234 · Published 4 Mar 2012

10.9734/BJMMR/2012/1016

Abstract

Purpose: To clarify the origin of a metallic intraocular foreign body (IOFB) due to a firecracker injury and to show the utility of X-ray diffraction analysis in the identification process. Methods: Interventional case report using X-ray diffraction technique. Results: We report a mechanism of firecracker ocular injury not previously described in the published literature. It involved penetration into the eye by a ground particle of calamine (originated from the area of detonation) and not, as it could be suspected, by a firecracker fragment. Conclusion: X-ray diffraction analysis showed environmental debris in the area of detonation can be injected as foreign material into the eye.

Intraocular foreign body firecracker injury X-ray diffraction analysis calamine endophthalmitis ultrasonography computed tomography

References (16)

  1. 1 X-ray fluorescence spectrometry [DOI]
  2. 2 Open globe injuries with positive intraocular cultures [DOI]
  3. 3 Opacification of Hydrophilic Acrylic Intraocular Lens Attributable to Calcification: Investigation on Mechanism [DOI]
  4. 4 MICROBIOLOGIC SPECTRUM AND VISUAL OUTCOME OF POSTTRAUMATIC ENDOPHTHALMITIS [DOI]
  5. 5 Treatment and Outcome of Traumatic Endophthalmitis in Open Globe Injury with Retained Intraocular Foreign Body [DOI]
  6. 6 Visual Outcome following Intraocular Foreign Bodies: A Retrospective Review of 5-Year Clinical Experience [DOI]
  7. 7 Risk Factors for Culture-Positive Endophthalmitis after Repair of Open Globe Injuries [DOI]
  8. 8 Eye injuries from fireworks in Western Sweden [DOI]
  9. 9 Work-Related Eye Injury: The Main Cause of Ocular Trauma in Iran [DOI]
  10. 10 Epidemiology of Open-Globe Trauma in the Southeast of Spain [DOI]
  11. 11 Comparison of the Clinical Presentation and Visual Outcome in Open Globe Injuries in Adults and Children over 30 Months [DOI]
  12. 12 Postoperative surface deposits on intraocular lenses in children [DOI]
  13. 13 Multiple Elements in the Deposits of Opacified Hydroview Intraocular Lens [DOI]
  14. 14 Teaching Chemistry Using October Sky [DOI]
  15. 15 Two remarkable events in the field of intraocular foreign body: (1) The reversal of siderosis bulbi. (2) The spontaneous extrusion of an intraocular copper foreign body.
  16. 16 Scanning Electron Microscopic and Energy-Dispersive X-Ray Analysis Findings on Two Brand New Intraocular Lenses [DOI]

Cited by 2

Transboundary sediment transfer from source to sink using a mineralogical analysis. Case study: Roseires Reservoir, Blue Nile, Sudan

Yasir S. A. Ali, Paolo Paron, Alessandra Crosato · International Journal of River Basin Management · 2017

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

6

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.