This study evaluated the effect of macro-encapsulation geometry on the sub-zero freezing behaviour of a 5% aqueous sodium chloride solution used as a phase change material in latent thermal energy storage units. Four containment geometries, namely cylindrical, square, triangular and rectangular profiles, were tested with an identical filling volume of 148 mL. Core temperature was recorded using thermocouples during cooling in a controlled freezer environment maintained at −18.0 °C. A numerical model was developed to describe the main thermal stages observed during freezing, including sensible cooling, supercooling, nucleation rebound and solid-state sub-cooling. The experimental temperature profiles showed that geometry influenced both the depth of supercooling and the subsequent cooling behaviour. The cylindrical cell exhibited the deepest supercooling, reaching −5.4 °C before nucleation, while the square, triangular and rectangular cells reached −3.5 °C, −3.7 °C and −3.1 °C, respectively. Model validation using experimental core-temperature data over a 33,500 s cooling period showed overall root mean square error values of 0.671 °C for the cylindrical cell, 0.221 °C for the square cell, 0.273 °C for the triangular cell and 0.312 °C for the rectangular cell. Heat transfer evaluation indicated that the rectangular geometry produced the highest steady-state energy extraction rate of 0.31 J/s, followed by the triangular, cylindrical and square geometries, with extraction rates of 0.27 J/s, 0.23 J/s and 0.21 J/s, respectively. The results indicate that container geometry governs freezing progression, model fit parameters, localised supercooling behaviour and steady-state heat extraction rates under sub-zero operating conditions.

Phase change material latent thermal energy storage sub-zero freezing supercooling sodium chloride brine macro-encapsulation geometry finite difference model cooling front heat extraction rate cold-chain storage

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

17

Page views

0

PDF downloads

1

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.